WD Series Products
This transmitter is compatible with our LR Series signal towers, which have been around since 2016.
WDT-4LR-Z2
Compatible Signal Tower : LR4 Series
Current consumption : typ.20mA
Communication range : line of sight 30m*
WDT-5LR-Z2
Compatible Signal Tower : LR5 Series
Current consumption : typ.20mA
Communication range : line of sight 30m*
WDT-6LR-Z2
Compatible Signal Tower : LR6 Series
Current consumption : typ.20mA
Communication range : line of sight 30m*
*Due to the characteristics of radio waves, this value is only a reference point.
Installing the Transmitter
Simply place the transmitter on the signal tower and twist to lock into place. No tools needed.
This transmitter is compatible with our LE and LME Series signal towers,
which have been around since 1998.
WDT-6M-Z2
Compatible Signal Tower : LME Series*1
Current consumption : typ.20mA
Communication range : line of sight 30m*2
WDT-5E-Z2
Compatible Signal Tower : LE series*1
Current consumption : typ.20mA
Communication range : line of sight 30m*2
*1 There are some restrictions to the compatibility of Signal Towers.
*2 Due to the characteristics of radio waves, this value is only a reference point.
*3 Please contact your local sales representative for the availability in your region.
Installing the Transmitter
Place the transmitter bracket A onto the signal tower and fasten with the center screw. Then attach the top cover B onto the bracket and twist until it is locked into place.
(One of the signal lines will need to be assigned as the power supply source.)
Transmitter Specifications | |||||
---|---|---|---|---|---|
Model Number | WDT-4LR-Z2 | WDT-5LR-Z2 | WDT-6LR-Z2 | WDT-5E-Z2 | WDT-6M-Z2 |
Compatible Signal Towers | LR4 Series | LR5 Series | LR6 Series | LE Series *1 | LME Series *1 |
Rated Voltage | 24V DC | ||||
Voltage Range | 19.0~26.4V DC | 21.6~26.4V DC | |||
Rated Current Consumption |
55mA | 20mA | |||
Ambient Operating Temperature | -10℃~+50℃ | -10℃~+60℃ | |||
Ambient Storage Humidity | 85%RH or less (no condensation) | ||||
Ambient Storage Temperature | -20℃~+60℃ | -20°C to 70°C (no freezing) | |||
Mounting Position | On top of body unit | On top of signal tower | |||
Mounting Location | Indoor | ||||
Mounting Direction | Upright | ||||
Protection Rating | IP65( IEC 60529)、NEMA TYPE 4X,13 | Conforms to that of the attached Signal Tower | |||
Mass | 70g | 74g | 85g | 52g | |
Number of Contacts | 6 points (Red, Amber, Green, Blue, White, Buzzer) | 4 points (choose 4 from Red, Amber, Green, Blue, White)*2 | |||
Input Reaction Time | 100msec or more | ||||
Display Unit | Status indicator | ||||
Operation Unit | Dip switches | ||||
External Contact Input | Control signal input |
*1 Some models are not compatible.
*2 1 point is used for power supply, so the number of contacts that can be used is 4.
Enables easy visualization of the 4Ms (Man, Machine, Material, Method).
WD PRO Transmitter
WDT-6LR-Z2-PRO
Compatible Signal Tower : LR6 Series
Current Consumption : max 110mA
(total value for transmitter and base unit)
Communication range : line of sight 20m*
*Due to the characteristics of radio waves, this value is only a reference point.
WD PRO Base Unit
WDB-D80S-PRO
RS-232C
Parallel : 8 contact inputs
Clear input
NOTE) This base unit is not compatible with WD-Z2 Series transmitters.
Transmitter Specifications | ||||
---|---|---|---|---|
Model Number | WDT-6LR-Z2-PRO | |||
Connectable Models | WDB-D80S-PRO | |||
Rated Voltage | 24V DC | |||
Operating Voltage Range | 24V DC ±10% | |||
Rated Current Consumption | max. 110mA (applied voltage: 24V DC) | |||
Ambient Operating Temperature | -10℃~+50℃ | |||
Ambient Operating Humidity | 85%RH or less (no condensation) | |||
Ambient Storage Temperature | -20℃~+60℃ | |||
Ambient Storage Humidity | 85%RH or less (no condensation) | |||
Mounting | Stacked on top of the WDB-D80S-PRO | |||
Mounting Location | Indoor | |||
Mounting Direction | Upright | |||
Protection Rating | IP65 (IEC 60529)、NEMA TYPE 4X,13 | |||
Mass | 90g | |||
Number of Contacts | 6 points (Red, Amber, Green, Blue, White, Buzzer) + 8 points (Binary 0 to 255) + 1 point (Clear input) | |||
Input Reaction Time | 100msec or more | |||
Display Unit | Status indicator | |||
Operation Unit | Dip switches | |||
External Control Input | Control signal input |